Availability: | |
---|---|
Quantity: | |
Applications of Load Cell
·Crane scale
·Hopper scale
·Packing scale
Introduction of Load Cell
WL3 tension load cell is designed for heavier duty applications. Capacities extend to 50 t ideal for crane, hopper and packing scale or more general purpose industrial weight measurement in process industries. All alloy steel and hermetically sealed is the ideal choice high accuracy industrial weighing machinery
Special features of Load Cell
·High capacity range from 2t to 50t
·Alloy steel construction
·Excellent dustproof
·Easy for installation and use
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 380±10Ω
Output resistance: 350±3Ω
Insulation resistance: 5000MΩ
Load Cell construction
Alloy Steel
Specifications | Technical data |
Rated capacity | 2 3 5 7 10 20 50 t |
Output sensitivity | 2.0±0.002 mV/V |
Non-linearity | ≤±0.05 %F.S. |
Hystersis | ≤±0.05 %F.S. |
Repeatability | ≤±0.03 %F.S. |
Creep | ±0.05 %F.S./30min |
Temperature effect on output | ±0.03 %F.S./10℃ |
Temperature effect on zero | ±0.05 %F.S./10℃ |
Zero output | <±1 %F.S. |
Insulation resistance | ≥5000MΩ |
Operating temperature range | -25~+70 ℃ |
Safe overload | 150 %F.S |
Ultimate overload | 300 %F.S |
Recommended excitation voltage(without amplifier) | 5~12 Vdc |
Maximum excitation voltage(without amplifier) | 18 Vdc |
Material | Alloy steel |
IP protection | IP65 |
Applications of Load Cell
·Crane scale
·Hopper scale
·Packing scale
Introduction of Load Cell
WL3 tension load cell is designed for heavier duty applications. Capacities extend to 50 t ideal for crane, hopper and packing scale or more general purpose industrial weight measurement in process industries. All alloy steel and hermetically sealed is the ideal choice high accuracy industrial weighing machinery
Special features of Load Cell
·High capacity range from 2t to 50t
·Alloy steel construction
·Excellent dustproof
·Easy for installation and use
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 380±10Ω
Output resistance: 350±3Ω
Insulation resistance: 5000MΩ
Load Cell construction
Alloy Steel
Specifications | Technical data |
Rated capacity | 2 3 5 7 10 20 50 t |
Output sensitivity | 2.0±0.002 mV/V |
Non-linearity | ≤±0.05 %F.S. |
Hystersis | ≤±0.05 %F.S. |
Repeatability | ≤±0.03 %F.S. |
Creep | ±0.05 %F.S./30min |
Temperature effect on output | ±0.03 %F.S./10℃ |
Temperature effect on zero | ±0.05 %F.S./10℃ |
Zero output | <±1 %F.S. |
Insulation resistance | ≥5000MΩ |
Operating temperature range | -25~+70 ℃ |
Safe overload | 150 %F.S |
Ultimate overload | 300 %F.S |
Recommended excitation voltage(without amplifier) | 5~12 Vdc |
Maximum excitation voltage(without amplifier) | 18 Vdc |
Material | Alloy steel |
IP protection | IP65 |
Load Cell dimensions:
Load Cell dimensions:
Load Cell order guide:
Load Cell order guide: