| Specifications | Technical Data | |||||||||
| Measuring ranges | 0~60...100...300...500...800kPa....1MPa...1.6MPa...3MPa...5MPa | |||||||||
| Overload pressures | 200%F.S | |||||||||
| Burst pressures | 500%F.S | |||||||||
| Operational Mode | Gauge Pressure, Absolute Pressure | |||||||||
| Measuring Media | Air (clean, non-corrosive, non-conductive gas) | |||||||||
| Output signal | 0.5~4.5VDC | |||||||||
| Operating voltage | 5VDC±0.25VDC | |||||||||
| Accuracy | ±0. 5%F. S(typ. ) | |||||||||
| Long-term drift | ≤0. 2%F. S/-(typ. ) | |||||||||
| Compensated temperature range | -20~+80℃ | |||||||||
| Operating temperature range | -40~+80℃/+135℃(Optional) | |||||||||
| Storage temperature range | -40~+125℃ | |||||||||
| Current consumption | ≤10mA 3conductor | |||||||||
| Insulation resistance | ≥100MΩ(100VDC) | |||||||||
| Vibration resistance | IEC 60068-2-6 (5…2000Hz, 20g) | |||||||||
| Shock resistance | IEC 60068-2-27 (50g, 11ms) | |||||||||
| EMC proof | IEC 61000-6-2/3/4 | |||||||||
| Material | 304Stainless Steel | |||||||||