Capacity range 5 kg ~ 150 kg
Compressive force measurement
Availability:
Quantity:
  • TH1
  • NS
  • NS-TH1-150kg

Applications of Load Cell

·Scale manufacturers (platform scales, legal-for-trade scales)

·Medicine (weighing hospital patients)

·Building industry (weighing materials, power shovels)

·Agriculture (automatic feeders)

·Public sector (weighing garbage)

·Quality assurance


Introduction of Load Cell

The compact and cost-effective TH1 force sensor reliably measures compressive force where space is a constraint. The force transducer allows for both dynamic and static measurement tasks to be solved. Due to the high fundamental frequency, TH1 is also suitable for very fast measurements. Its welded design from stainless steel makes the force sensor extremely robust.


Special features of Load Cell

·Designed with metal foil strain gauge technology

·High precision, overload protection, excellent stability

·Dynamic measurement

·Excellent dustproof

·Easy for installation and use


Load Cell electric specification

Power supply: 5~24VDC

Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)

Input resistance: 380±10Ω

Output resistance: 350±3Ω

Insulation resistance: 2000MΩ


Load Cell construction 

Alloy steel


SpecificationsTechnical data

Rated capacity

5        10       30        100        150kg
Output sensitivity 2.0±0.002                                          mV/V
Non-linearity ≤±0.03                                                %F.S.
Hystersis≤±0.03                                                 %F.S.
Repeatability≤±0.03                                                 %F.S.
Creep±0.03                                        %F.S./30min
Temperature effect on output ±0.03                                         %F.S./10℃
Temperature effect on zero±0.03                                         %F.S./10℃
Zero output<±1                                                    %F.S.
Insulation resistance≥2000MΩ
Operating temperature range -25~+70                                                  ℃
Safe overload150                                                     %F.S
Ultimate overload300                                                    %F.S
Recommended excitation voltage(without amplifier)5~12                                                   Vdc
Maximum excitation voltage(without amplifier)18                                                       Vdc
MaterialStainless steel
IP protectionIP65


Load Cell dimensions:

th1-dimension

Load Cell order guide:

th1-ordering

Previous: 
Next: 

PRODUCT CATEGORY

Product Inquire
TM Sensor Co., Ltd.(Sensor BU)
TM Automation Instruments Co., Ltd.
(Headquarters)

QUICK LINKS

PRODUCTS CATEGORY

CONTACT US

   Add : 16F.Building 11. No.518 Xinzhuan Road, Shanghai ,China
    Phone : +86-18917346849
  Tel : +86-021-57778012
   E-mail : weiwei@tmvenus.com
   Skype : tanxi21

Copyright  2019  TM Automation Instruments Co., Ltd.                                  沪ICP备17037612号
Sitemap