Availability: | |
---|---|
Quantity: | |
Applications of Load Cell
·Scale manufacturers (platform scales, legal-for-trade scales)
·Medicine (weighing hospital patients)
·Building industry (weighing materials, power shovels)
·Agriculture (automatic feeders)
·Public sector (weighing garbage)
·Quality assurance
Introduction of Load Cell
TH4 load cells are perfectly suited for use with any type of tank, batching or platform scales as well as for level monitoring - and are used by market leaders. Precise measurement results up to accuracy class C3 per OIML R60. The particularly robust TH4 load cells are available in standard dimensions and can be easily integrated and quickly adapted to the required maximum capacities ranging from 50 kg to 20 tons
Special features of Load Cell
·Shear beam constructure
·High precision
·Excellent dustproof
·Easy for installation and use
Applications of Load Cell
·Scale manufacturers (platform scales, legal-for-trade scales)
·Medicine (weighing hospital patients)
·Building industry (weighing materials, power shovels)
·Agriculture (automatic feeders)
·Public sector (weighing garbage)
·Quality assurance
Introduction of Load Cell
TH4 load cells are perfectly suited for use with any type of tank, batching or platform scales as well as for level monitoring - and are used by market leaders. Precise measurement results up to accuracy class C3 per OIML R60. The particularly robust TH4 load cells are available in standard dimensions and can be easily integrated and quickly adapted to the required maximum capacities ranging from 50 kg to 20 tons
Special features of Load Cell
·Shear beam constructure
·High precision
·Excellent dustproof
·Easy for installation and use
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 380±10Ω
Output resistance: 350±3Ω
Insulation resistance: 2000MΩ
Load Cell construction
Alloy steel
Specifications | Technical data |
Rated capacity | 0.05 0.5 1 10 20 t |
Output sensitivity | 2.0±0.002 mV/V |
Non-linearity | ≤±0.03 %F.S. |
Hystersis | ≤±0.03 %F.S. |
Repeatability | ≤±0.03 %F.S. |
Creep | ±0.03 %F.S./30min |
Temperature effect on output | ±0.03 %F.S./10℃ |
Temperature effect on zero | ±0.03 %F.S./10℃ |
Zero output | <±1 %F.S. |
Insulation resistance | ≥2000MΩ |
Operating temperature range | -25~+70 ℃ |
Safe overload | 150 %F.S |
Ultimate overload | 300 %F.S |
Recommended excitation voltage(without amplifier) | 5~12 Vdc |
Maximum excitation voltage(without amplifier) | 18 Vdc |
Material | Alloy steel |
IP protection | IP65 |
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 380±10Ω
Output resistance: 350±3Ω
Insulation resistance: 2000MΩ
Load Cell construction
Alloy steel
Specifications | Technical data |
Rated capacity | 0.05 0.5 1 10 20 t |
Output sensitivity | 2.0±0.002 mV/V |
Non-linearity | ≤±0.03 %F.S. |
Hystersis | ≤±0.03 %F.S. |
Repeatability | ≤±0.03 %F.S. |
Creep | ±0.03 %F.S./30min |
Temperature effect on output | ±0.03 %F.S./10℃ |
Temperature effect on zero | ±0.03 %F.S./10℃ |
Zero output | <±1 %F.S. |
Insulation resistance | ≥2000MΩ |
Operating temperature range | -25~+70 ℃ |
Safe overload | 150 %F.S |
Ultimate overload | 300 %F.S |
Recommended excitation voltage(without amplifier) | 5~12 Vdc |
Maximum excitation voltage(without amplifier) | 18 Vdc |
Material | Alloy steel |
IP protection | IP65 |
Load Cell dimensions:
Load Cell dimensions:
Load Cell order guide:
Load Cell order guide: