Mechanical Capacitive Truck Scale High Accuracy Load Cell
You are here: Home » Products » Load Cell » Mechanical Capacitive Truck Scale High Accuracy Load Cell

loading

Share to:

Mechanical Capacitive Truck Scale High Accuracy Load Cell

Capacity range 0.1~150t wide range
S-beam design, both tension and compression
High accuracy, water-proof, anti-corrosion
Widely applied in the electronic truck scale, crane scale and hopper scale
Availability:
Quantity:
  • WL2

  • NS

  • NS-WL2-150 ton

Applications of Load Cell

·Scale manufacturers (platform scales, legal-for-trade scales)

·Medicine (weighing hospital patients)

·Building industry (weighing materials, power shovels)

·Agriculture (automatic feeders)

·Public sector (weighing garbage)

·Quality assurance


Introduction of Load Cell

Tension Compression load cell is ideal for use in static and quasi-static weighing tasks; for instance, for the gravimetric level measurement of suspended tanks as well as for conveyor, batching, and hybrid scales. It is available in seven maximum capacities, which range from 0.1 t to 150 t, thus covering a very broad range, the product is widely used for various scale, industrial weighing system.


Special features of Load Cell

·S-beam design,Both tension and compression force

·Wide measuring range up to 150 ton

·Excellent overload capacity

·High accuracy, water-proof, anti-corrosion


Load Cell electric specification

Power supply: 5~24VDC

Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)

Input resistance: 380±10Ω

Output resistance: 350±3Ω

Insulation resistance: 2000MΩ


Load Cell construction 

Alloy steel


SpecificationsTechnical data

Rated capacity

0.1      0.5       1       5       8       10       20       150 ton
Output sensitivity1.5~2.0±0.002                                            mV/V
Non-linearity≤±0.05                                                  %F.S.
Hystersis≤±0.05                                                  %F.S.
Repeatability≤±0.03                                                  %F.S.
Creep±0.03                                         %F.S./30min
Temperature effect on output ±0.02                                           %F.S./10℃
Temperature effect on zero±0.05                                           %F.S./10℃
Input resistance380±10                                                        Ω
Output resistance350±3                                                          Ω
Zero output<±1                                                        %F.S.
Insulation resistance≥2000MΩ
Operating temperature range -25~+70                                                       ℃
Safe overload150                                                         %F.S
Ultimate overload300                                                         %F.S
Recommended excitation voltage(without amplifier)5~12                                                       Vdc
Maximum excitation voltage(without amplifier)15                                                           Vdc
MaterialAlloy steel
IP protectionIP65


Load Cell dimensions:

wl2 dimension 1

Load Cell order guide:

wl2 order guide