Industrial Hydraulic Straightpoint Force Load Cell
You are here: Home » Products » Load Cell » Industrial Hydraulic Straightpoint Force Load Cell
Share to:

Industrial Hydraulic Straightpoint Force Load Cell

Capacity range 50 kg ~ 2 t
Both tension and compression
High accuracy, water-proof, anti-corrosion
Widely applied in the electronic scale, crane scale and wire rope tension

Quantity:
  • WL5
  • NS
  • NS-WL5-2ton

Applications of Load Cell

·Scale manufacturers (platform scales, legal-for-trade scales)

·Medicine (weighing hospital patients)

·Building industry (weighing materials, power shovels)

·Agriculture (automatic feeders)

·Public sector (weighing garbage)

·Quality assurance


Introduction of Load Cell

Tension Compression load cell is ideal for use in static and quasi-static weighing tasks; for instance, for the gravimetric level measurement of suspended tanks as well as for conveyor, batching, and hybrid scales. It is available in seven maximum capacities, which range from 50 kg to 2 t, thus covering a very broad range, the product is widely used for various scale, industrial weighing system.


Special features of Load Cell

·Both tension and compression force

·Wire rope tension measurement and controlling 

·High precision

·Excellent dustproof

·High accuracy, water-proof, anti-corrosion


Load Cell electric specification

Power supply: 5~24VDC

Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)

Input resistance: 380±10Ω

Output resistance: 350±3Ω

Insulation resistance: 5000MΩ


Load Cell construction 

Stainless steel


SpecificationsTechnical data

Rated capacity

0.05         0.1          0.2          0.5          1          2  t
Output sensitivity 1.5±0.002                                            mV/V
Non-linearity≤±0.05                                                  %F.S.
Hystersis≤±0.05                                                  %F.S.
Repeatability≤±0.05                                                  %F.S.
Creep±0.05                                         %F.S./30min
Temperature effect on output ±0.03                                           %F.S./10℃
Temperature effect on zero±0.05                                           %F.S./10℃
Input resistance380±10                                                        Ω
Output resistance350±3                                                          Ω
Zero output<±2                                                        %F.S.
Insulation resistance≥5000MΩ
Operating temperature range -40~+80                                                       ℃
Safe overload150                                                         %F.S
Ultimate overload300                                                         %F.S
Recommended excitation voltage(without amplifier)5~12                                                       Vdc
Maximum excitation voltage(without amplifier)18                                                           Vdc
MaterialStainless steel
IP protectionIP65


Load Cell dimensions:

wl5 dimension

Load Cell order guide:

wl5 order guide

Product Inquire
TM Automation Instruments Co., Ltd

QUICK LINKS

PRODUCTS CATEGORY

CONTACT US

   Add : 16F.Building 11. No.518 Xinzhuan Road, Shanghai ,China
    Phone : +86-18917346849
  Tel : +86-021-57778012
   E-mail : weiwei@tmvenus.com
   Skype : tanxi21
Copyright  2019  TM Automation Instruments Co., Ltd.                                  沪ICP备17037612号