Availability: | |
---|---|
Quantity: | |
Applications of Load Cell
·Scale manufacturers (platform scales, legal-for-trade scales)
·Medicine (weighing hospital patients)
·Building industry (weighing materials, power shovels)
·Agriculture (automatic feeders)
·Public sector (weighing garbage)
·Quality assurance
Introduction of Load Cell
Tension Compression load cell is ideal for use in static and quasi-static weighing tasks; for instance, for the gravimetric level measurement of suspended tanks as well as for conveyor, batching, and hybrid scales. It is available in seven maximum capacities, which range from 5 kg to 20000 kg, thus covering a very broad range, the product is widely used for various scale, industrial weighing system.
Special features of Load Cell
·S-beam design,Both tension and compression force
·High precision
·Excellent dustproof
·High accuracy, water-proof, anti-corrosion
Applications of Load Cell
·Scale manufacturers (platform scales, legal-for-trade scales)
·Medicine (weighing hospital patients)
·Building industry (weighing materials, power shovels)
·Agriculture (automatic feeders)
·Public sector (weighing garbage)
·Quality assurance
Introduction of Load Cell
Tension Compression load cell is ideal for use in static and quasi-static weighing tasks; for instance, for the gravimetric level measurement of suspended tanks as well as for conveyor, batching, and hybrid scales. It is available in seven maximum capacities, which range from 5 kg to 20000 kg, thus covering a very broad range, the product is widely used for various scale, industrial weighing system.
Special features of Load Cell
·S-beam design,Both tension and compression force
·High precision
·Excellent dustproof
·High accuracy, water-proof, anti-corrosion
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 380±10Ω
Output resistance: 350±3Ω
Insulation resistance: 2000MΩ
Load Cell construction
Alloy steel
Specifications | Technical data |
Rated capacity | 5 10 20 30 50 100 20000 KG |
Output sensitivity | 2.0±0.002 mV/V |
Non-linearity | ≤±0.02 %F.S. |
Hystersis | ≤±0.02 %F.S. |
Repeatability | ≤±0.02 %F.S. |
Creep | ±0.03 %F.S./30min |
Temperature effect on output | ±0.02 %F.S./10℃ |
Temperature effect on zero | ±0.02 %F.S./10℃ |
Input resistance | 380±10 Ω |
Output resistance | 350±3 Ω |
Zero output | <±1 %F.S. |
Insulation resistance | ≥5000MΩ |
Operating temperature range | -25~+70 ℃ |
Safe overload | 150 %F.S |
Ultimate overload | 300 %F.S |
Recommended excitation voltage(without amplifier) | 5~12 Vdc |
Maximum excitation voltage(without amplifier) | 15 Vdc |
Material | Alloy steel |
IP protection | IP67 |
Load Cell electric specification
Power supply: 5~24VDC
Various optional output signal: 2.0mV/V, (if connect with amplifier, 4~20mA, 0~5V, 0~10V etc)
Input resistance: 380±10Ω
Output resistance: 350±3Ω
Insulation resistance: 2000MΩ
Load Cell construction
Alloy steel
Specifications | Technical data |
Rated capacity | 5 10 20 30 50 100 20000 KG |
Output sensitivity | 2.0±0.002 mV/V |
Non-linearity | ≤±0.02 %F.S. |
Hystersis | ≤±0.02 %F.S. |
Repeatability | ≤±0.02 %F.S. |
Creep | ±0.03 %F.S./30min |
Temperature effect on output | ±0.02 %F.S./10℃ |
Temperature effect on zero | ±0.02 %F.S./10℃ |
Input resistance | 380±10 Ω |
Output resistance | 350±3 Ω |
Zero output | <±1 %F.S. |
Insulation resistance | ≥5000MΩ |
Operating temperature range | -25~+70 ℃ |
Safe overload | 150 %F.S |
Ultimate overload | 300 %F.S |
Recommended excitation voltage(without amplifier) | 5~12 Vdc |
Maximum excitation voltage(without amplifier) | 15 Vdc |
Material | Alloy steel |
IP protection | IP67 |
Load Cell dimensions:
Load Cell dimensions:
Load Cell order guide:
Load Cell order guide: